• 1/1

Air Driven Liquid Pump of AH Series

Detail

Maximum output pressure: 8.3MPa;Working pressure: 7MPa;Booster ratio: 1:10 3 Working medium: water, oil;Driving medium: compressed air;The pressure range of drive air inlet is 0.1-0.83MPa (for the sake of product service life, it is recommended that the drive air inlet pressure be 0.7MPa);Maximum air consumption based on 0.7MPa driving air pressure: 1m ³/ min;Displacement per stroke: 157.08ML;Interface size of

high-pressure inlet and outlet check valve: PT3/4".


Air Driven Liquid Pump of AH Series

Based on static pressure, the air consumption is 1.0m³ when the air pressure is 7Bar.   

Model

Piston/Rod

DiameterΦ( mm)

Flow per stroke

(mL)

IN

OUT

Max output Po (bar)@

drive 8.3bar

Output liquid Po( bar)   1bar=0.1MPa=1.019Kg/cm²

0

20

40

70

100

150

200

300

400

500

600

700

900

1200

1700

2350

FlowL/min

AH02

100

471.24

PT3/4"

PT3/4"

20.7

56.55

0















AH04

80

402.12

PT3/4"

PT3/4"

33.2

48.25

16.08















AH07

63

249.38

PT3/4"

PT3/4"

49.6

29.93

9.98

4.99














AH10

50

157.08

PT3/4"

PT3/4"

83

18.85

12.57

9.42

0













AH16

40

100.53

PT3/4"

PT3/4"

132.8

12.06

9.05

7.04

6.03

4.02












AH20

35

76.97

PT3/4"

PT3/4"

166

9.24

7.7

6.93

6.16

5.39

0











AH28

30

56.55

PT1/2"

PT1/2"

232.4

6.79

5.66

5.09

4.52

3.96

3.39

0










AH40

25

39.27

PT1/2"

PT1/2"

332

4.71

3.93

3.53

3.14

2.75

2.36

1.96

0









AH64

20

25.13

NPT3/8"

NPT3/8"

498

3.02

2.51

2.26

2.01

1.76

1.51

1.26

1.01

0.75








AH80

18

20.36

NPT3/8"

NPT3/8"

664

244

2.04

1.83

1.63

143

1.22

1.02

0.81

0.71

0.61







AH100

16

16.08

NPT3/8"

NPT3/8"

830

1.93

1.77

1.61

1.53

1.37

1.21

0.96

0.8

0.64

0.56

0.48

0





AH130

14

12.32

NPT3/8"

NPT3/8"

1079

1.48

1.42

1.36

1.23

1.11

0.99

0.86

0.74

0.62

0.49

0.43

0.37

0.12




AH170

12

6.79

NPT3/8"

NPT3/8"

1411

0.81

0.78

0.75

0.71

0.68

0.61

0.54

0.48

0.41

0.34

0.27

0.24

0.2

0.07



AH240

10

4.71

NPT3/8"

NPT1/4"

1992

0.57

0.54

0.52

0.49

0.47

0.42

0.38

0.33

0.28

0.24

0.19

0.16

0.14

0.12

0.09


AH300

9

3.82

NPT1/4"

※HF4

2490

0.46

0.44

0.44

0.42

0.4

0.38

0.34

0.31

0.27

0.23

0.19

0.17

0.15

0.12

0.1


AH400

8

3.02

NPT1/4"

※HF4

3320

0.36

0.35

0.35

0.33

0.32

0.3

0.27

0.24

0.21

0.18

0.15

0.14

0.12

0.11

0.11

0.08

Installation Dimensions/mm

Model

Drive gas interface

(AIR IN

A

B

C

D

E

F

G

Mounting Hole

Weight/kg

AH02

G1/2"

391

218

162

94

240

172

100

4-φ12*22

15

AH04

G1/2"

412

218

184

94

240

172

100

4-φ12*22

15

AH07

G1/2"

391

218

162

94

240

172

100

4-φ12*22

15

AH10

G1/2"

391

218

162

94

240

172

100

4-φ12*22

15

AH16

G1/2"

349

218

120

94

240

172

100

4-φ12*22

17

AH20

G1/2"

332

218

103

94

240

172

100

4-φ12*22

16

AH28

G1/2"

332

218

103

94

240

172

100

4-φ12*22

14

AH40

G1/2"

332

218

103

94

240

172

100

4-φ12*22

14

AH64

G1/2"

332

218

103

94

240

172

100

4-φ12*22

14

AH80

G1/2"

339

218

110

94

240

172

100

4-φ12*22

14

AH100

G1/2"

339

218

110

94

240

172

100

4-φ12*22

14

AH130

G1/2"

339

218

110

94

240

172

100

4-φ12*22

14

AH170

G1/2"

300

208

81

94

240

172

100

4-φ12*22

13

AH240

G1/2"

300

208

81

94

240

172

100

4-φ12*22

14

AH300

G1/2"

300

208

81

94

240

172

100

4-φ12*22

14

AH400

G1/2"

300

208

81

94

240

172

100

4-φ12*22

14

    AH series gas-liquid booster pump is a single-drive single-acting liquid booster pump with compressed air, which has the advantages of high safety and high output pressure.

Features


1. The output pressure can reach up to 3320bar;
2. The gas drive ensures that the medium does not generate heat, sparks and flames during the transmission process, and the pressurization is safe;
3. The driving gas pipeline does not need to be lubricated, which saves costs and prevents pollution;
4. It is suitable for most liquids and liquefied gases, and can maintain pressure without energy consumption at a predetermined pressure, automatically absorb liquid, automatically maintain pressure, and automatically replenish pressure;
5. The product has compact structure, strong reliability and application fields;

Main features


1. AH series is based on static pressure, when the driving air pressure is 7bar, the air consumption is 1.0m3/min;
2. The driving pressure is 1bar-8.3bar (14.5-120.35psi), and the AH series is a single driving piston (Φ160mm);
3. The high-pressure end is made of stainless steel, and the driving part is made of aluminum alloy;
4. The medium of AH series standard products is water and oil, and the order code is: AH64 (series code + boost ratio);

Description of special products


About medium: AH series can be applied to various media such as brake fluid, liquefied gas, etc., order code such as: AH20-CO2(series code + boost ratio + boost medium)
About the interface: If you need a special interface, please specify when ordering.

Application scenarios


1. AH series gas-liquid booster pump is suitable for occasions where pressure maintenance, supplementary pressure and high frequency work are required;
2. Hydraulic test/burst test (including but not limited to pressure components such as valves, pressure vessels, pressure switches, hoses, blowout preventers, etc.); calibration of pressure gauges and sensors;
3. Vehicle braking system test, fuel injector test;
4. Power source of hydraulic tools (bolt tensioner, hydraulic nut, etc.);
5. Power source and control source of wellhead equipment;
6. The power source of the pneumatic hydraulic station;

16.jpg17.jpg