• 1/1

Air Driven Liquid Pump of AT Series

Detail

Maximum output pressure: 33.2MPa;Boost ratio: 1:4;Working medium: non corrosive liquid;Driving medium: compressed air;The pressure range of drive air inlet is 0.1-0.83MPa (for the sake of product service life, it is recommended that the drive air inlet pressure be 0.7MPa);Maximum air consumption based on 0.7MPa driving air pressure: 1m ³/ minDisplacement per stroke: 401.2ML;Low pressure medium inlet connector size: PT3/4 ";High pressure medium outlet connector size: PT3/4 ".


Product Parameter

Air Driven Liquid Pump of AT Series

Based on static pressure, the air consumption is 1.0m³ when the air pressure is 7Bar.   

Model

Piston/Rod Diameter

Φ ( mm)

Flow per stroke( ml)

IN

OUT

Max gas outlet Po (bar)@drive 8.3bar

Output liquid Po(bar)   1bar=0.1MPa=1.019Kg/cm²

0

20

40

70

100

150

200

300

400

500

600

700

900

1200

1700

2350

FlowL/min)

AT04

80

401.92

PT3/4"

PT3/4"

33.2

















AT07

63

249.25

PT3/4"

PT3/4"

58.1

















AT10

50

235.5

PT3/4"

PT3/4"

83

















AT16

40

188.5

PT3/4"

PT3/4"

132.8

22.62

17

13.2

11.3

4.71












AT20

35

144.32

PT3/4"

PT3/4"

166

17.32

14.43

12.99

11.55

10.1

0











AT28

30

106.03

PT1/2"

PT1/2"

232.4

12.72

10.6

9.54

8.48

7.42

6.36

0










AT40

25

73.63

PT1/2"

PT1/2"

332

8.84

7.36

6.63

5.89

5.15

4.42

3.68

0









AT64

20

47.12

PT3/8"

NPT3/8"

498

5.65

4.71

4.24

3.77

3.3

2.83

2.36

1.88

1.41








AT80

18

38.17

PT3/8"

NPT3/8"

664

4.58

3.82

3.44

3.05

2.67

2.29

1.91

1.53

1.34

1.15







AT100

16

30.16

PT3/8"

NPT3/8"

830

3.62

3.32

3.02

2.87

2.56

2.26

1.81

1.51

1.21

1.06

0.9

0





AT130

14

23.09

PT3/8"

NPT3/8"

1079

2.77

2.66

2.54

2.31

2.08

1.85

1.62

1.39

1.15

0.92

0.81

0.69

0.23




AT170

12

12.44

PT3/8"

NPT3/8"

1411

1.49

1.43

1.37

1.31

1.24

1.12

1

0.87

0.75

0.62

0.5

0.44

0.37

0.12



AT240

10

8.64

PT3/8"

※HF4

1992

1.04

0.99

0.95

0.91

0.86

0.78

0.69

0.6

0.52

0.43

0.35

0.3

0.26

0.22

0.17


AT300

9

7

NPT1/4"

※HF4

2490

0.84

0.81

0.81

0.77

0.74

0.7

0.63

0.56

0.49

0.42

0.35

0.32

0.28

0.32

0.18


AT400

8

5.53

NPT1/4"

※HF4

3320

0.66

0.64

0.64

0.61

0.58

0.55

0.5

0.44

0.39

0.33

0.28

0.25

0.22

0.21

0.19

0.14

Installation Dimensions/mm

Model

Drive gas interface
(AIR IN

A

B

C

D

E

F

G

H

Mounting Hole

Weight/kg

AT04

G1/2"

575.8

218

178.8

94

240

172

100

/

4-φ12*22

22

AT07

G1/2"

538

218

160

94

240

172

100

/

4-φ12*22

19

AT10

G1/2"

542

218

162

94

240

172

100

320

4-φ12*22

20

AT16

G1/2"

453

218

115

94

240

172

100

320

4-φ12*22

23

AT20

G1/2"

458

218

120

94

240

172

100

320

4-φ12*22

23

AT28

G1/2"

424

218

103

94

240

172

100

320

4-φ12*22

18

AT40

G1/2"

424

218

103

94

240

172

100

320

4-φ12*22

18

AT64

G1/2"

424

218

103

94

240

172

100

290

4-φ12*22

18

AT80

G1/2"

438

218

110

94

240

172

100

280

4-φ12*22

18

AT100

G1/2"

438

218

110

94

240

172

100

280

4-φ12*22

18

AT130

G1/2"

438

218

110

94

240

172

100

320

4-φ12*22

18

AT170

G1/2"

370

208

81

94

240

172

100

320

4-φ12*22

18

AT240

G1/2"

370

208

81

94

240

172

100

320

4-φ12*22

17

AT300

G1/2"

370

208

81

94

240

172

100

320

4-φ12*22

17

AT400

G1/2"

370

208

81

94

240

172

100

320

4-φ12*22

17

AT series gas-liquid booster pump is a single-drive double-acting liquid booster pump with compressed air, which has the advantages of high safety, high output pressure and larger flow.

Features


1. The output pressure can reach up to 3320bar, and the output flow is larger than that of the AH series under the same pressure ratio;
2. The gas drive ensures that the medium does not generate heat, sparks and flames during the transmission process, and the pressurization is safe;
3. The driving gas pipeline does not need to be lubricated, which saves costs and prevents pollution;
4. It is suitable for most liquids and liquefied gases, and can maintain pressure without energy consumption at a predetermined pressure, automatically absorb liquid, automatically maintain pressure, and automatically replenish pressure;
5. The product has compact structure, strong reliability and application fields;

Main features


1. AT series is based on static pressure, when the driving air pressure is 7bar, the air consumption is 1.0m3/min;
2. The driving pressure is 1bar-8.3bar (14.5-120.35psi), and the AT series is a single driving piston (Φ160mm)
3. The high-pressure end is made of stainless steel, and the driving part is made of aluminum alloy;
4. The medium of AT series standard products is water and oil, and the order code is: AT64 (series code + boost ratio)
Description of special products:
About medium: AT series can be applied to various media such as brake fluid and liquefied gas, order code such as: AT20-CO2(series code + boost ratio + boost medium)
About the interface: If you need a special interface, please specify when ordering.

Application scenarios


1. AT series gas-liquid booster pump is suitable for occasions with high output pressure and flow requirements;
2. Hydraulic test/burst test (including but not limited to valves, pressure vessels, pressure switches, hoses, BOPs and other pressurized components;
3. Boosting of vehicle braking system;
4. Calibration of pressure gauges and sensors;
5. Water jet for cutting and cleaning;
6. Leak test, oil and gas well shutdown system;
7. Operation and control of wellhead equipment;