Use:
HZL can be widely applied in metallurgy, machinery, chemical engineering, mine and other fields. It can purify kinds of lubricating oil with high viscosity, quickly remove water content, mechanical impurities and gas volatile (as ammonia), which can enhance quality of oil, resume utilization capacity of lubricating oil and guarantee normal operation of the system. This purifier can work online. Besides it can preheat oil tank, then filter the oil separately to meet customer’s requirement for the oil.
Feature:
l Use special oil pump to transport oil.
l Super dehydration and degassing system, quickly separating water content and gas in the oil.
l Precise multi-stage filtration system, high quality filter element of better ability of contaning pollutants and long service life.
l Optimized electric heating system with automatic constant temperature controller ensures that oil temperature to be even and stable.
l An advanced fully automatic temperature controlling system, liquid-level controlling system, defoaming controlling system, pressure protecting system and excellent equipment can ensure operation of the equipment with high performance.
l It can purify any kinds of high viscosity lubricating oil online, and with its lamps indicative of the condition for operation.
l It is humanization design with low noise, deep purification and longtime free maintenance to save cost from the running process.
Optional mode:
l The customer's request can be met buy adopting PLC intelligent and displaying dynamically.
l Available in mobile option, stationary option, and car-carrying option.
l Kinds of filters can be made hermetical, canopy-covering or open-air.
l Various sizes and configuration (alloy shield) are available.
Technical Parameter List
Item | ParamName | Unit | HZL-20 | HZL-30 | HZL-50 | HZL -80 | HZL -100 | HZL -150 | HZL -200 | HZL -300 | ||
Technical Parameter | Flow | L/H | 1200 | 1800 | 3000 | 4800 | 6000 | 9000 | 12000 | 18000 | ||
Operating Vacuum Degree | MPa | -0.06 ~ -0.096 | ||||||||||
Working Pressure | MPa | ≤0.5 | ||||||||||
Temperature Range | ℃ | 20~80 | ||||||||||
Power Supply | V | 380V/50Hz (or at user’s option) | ||||||||||
Working Noise | dB(A) | ≤78 | ||||||||||
Heating Power | Kw | 24 | 24 | 30 | 45 | 60 | 90 | 135 | 180 | |||
Total Power | Kw | 25.1 | 25.1 | 31.65 | 47.6 | 63 | 95.5 | 142 | 191 | |||
Pipeline Diameter | mm | 25 | 25 | 32 | 40 | 40 | 50 | 50 | 65 | |||
Net Weight | Kg | 400 | 450 | 550 | 650 | 680 | 850 | 900 | 1200 | |||
Overall Dimensions
| length | mm | 1000 | 1070 | 1200 | 1300 | 1300 | 1450 | 1450 | 1600 | ||
width | mm | 1000 | 1000 | 1150 | 1250 | 1250 | 1450 | 1450 | 1600 | |||
height | mm | 1500 | 1550 | 1750 | 1800 | 1800 | 2150 | 2150 | 2250 | |||
Index for Oil Treatment | Water Content | % | No (GB/T260) | |||||||||
Gas Content | % | ≤0.1 (GB/T423) | ||||||||||
Mechanical Impurity | % | No (GB/T511) |